Compuprint 10200 Programmer Manual Instrukcja Użytkownika Strona 97

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 234
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 96
Commands
93
UPC-EAN 5
DC4 DC4 ESC !
n 6 p EM
ADD ON-5 bar code data fields contain numeric data only: question marks will
be printed in place of HRC string otherwise, if possible.
If 6-digit strings will be received within a DC4 DC4 ESC (... EM control
sequence and o check-digit option field is missing or takes NULL value, the
symbol will encode the first 5 digits and the 6
th
received digit will be used as
check digit, even though this may affect its readability; if o check digit option
takes 1 value, the 6
th
digit is matched versus the internally generated check-
digit an question marks will printed in place of HRC string when mismatching,
if possible.
If 5-digit strings will be received and o check digit field is missing or takes
NULL value, question marks will be printed in place of HRC string, if possible;
if o field takes value 1, the check digit will be computed applying the internally
available algorithm to the received string in order to properly encode the
symbol
If f field is missing or takes value 1, the 5-digits HRC string will be printed
above the Bar/Spaces symbol and its height will be part of the overall symbols
height; the check-digit will never show on HRC string. If f field takes value 0,
the symbols encoding will print at full height.
Przeglądanie stron 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 233 234

Komentarze do niniejszej Instrukcji

Brak uwag